Grundfos Low Water Pressure Booster Pump 13 GPM 3/4 HP 230 V, MQ3-35-230
Grundfos Pumps low water pressure booster pumps are designed for domestic applications where low noise is a major consideration. The water cooled unit eliminates the need for noisy cooling fans. Up to 3 water outlets can be operated at the same time without substantially reducing performance.
| Capacity Table # MQ3-35-230 In Gallons Per Minute | |||||||
|---|---|---|---|---|---|---|---|
| Model | HP | Head In PSI | Shut-off | ||||
| 30 | 35 | 40 | 45 | ||||
| Gallons Per Minute (GPM) | |||||||
| MQ3-25-230 | 3/4 | 13 | 10 | 6 | 4 | 50 PSI | |
Specifications
Applications: Domestic water supply. Pressure boosting from well or city. Automatic water transfer. Type of pump: Single stage, self-priming centrifugal Pump construction: 304 Stainless steel and corrosion-resistant materials. Inlet & outlet: 1" MNPT X 1" MNPT(male pipe thread) Cut-in pressure: 30 PSI factory setting Maximum operating pressure: 109 PSI (Suction pressure plus discharge pressure cannot exceed 109 PSI) Tank size: 0.7 Gallons Suction lift: Capable of up to 25 feet Maximum inlet pressure: 44 PSI (Must install a pressure reducing valve on the suction side of the pump if the inlet pressure is more than 44 PSI) Electrical: 220-240 volts, 1 phase, 3.7 Amps., 60 Hz, 850 Watts, 3/4 HP, TEFC motor. Includes 6' electrical cord with bare leads Maximum water temperature: 95 degrees Fahrenheit Carton Dimensions: 24" high, 24" long, 12" wide. Weight: 30 lbs
| Maximum Flow Rate Of Typical Residential Water Meters | ||
|---|---|---|
| Meter Size | Maximum Flow (GPM) | Caution |
| 5/8" | 12 | Before ordering the booster system |
| 3/4" | 30 | make sure that your water demands |
| 1" | 40 | do not exceed the maximum flow rate |
| 1-1/4 | 65 | of your house water meter.. |
GRU-MQ-Boosters-Bulletin.pdf | GRU-MQ-Boosters-Manual.pdf |
GRU-MQ-Boosters-Adjustment.pdf | GRU-MQ-Boosters-Check-List.pdf |
GRU-MQ-Warranty-Statement.pdf |
Questions & Answers
- What causes the MQ to start?
- The pump will start when the flow rate is greater than 0.3 gpm OR the pressure is below 29 psi.
- What causes the MQ to stop?
- The pump will shut off in 12-15 seconds after flow stops. Additionally, the MQ will be turned off in the event of a dry-run or over temperature alarm.
- What is the maximum height recommended between the MQ and any tap?
- To allow for the pressure of 50 ft of water, tolerances and a safety margin, Grundfos recommends a maximum height of 50 ft between the MQ and any tap
- What is the purpose of the built-in pressure tank?
- It is designed to minimize motor startup due to small leaks.
- How is the dry-run condition determined?
- The dry-run alarm is declared when the motor is running AND the flow rate is less than 0.3 gpm and when the pressure is less than the pressure switch setting.
- What is the maximum inlet pressure allowed in the MQ?
- The maximum inlet pressure for the MQ3-35 is 50 psi…..The maximum inlet pressure for the MQ 3-45 is 40 psi The inlet pressure plus the MQ boosted pressure must not exceed 109 psi.
- Where can a pressure gauge be easily installed?
- In the ˝" straight thread opening used to add priming water to the pump.
. Click here
| About Us Contact Us Customer Reviews | Facebook Twitter | Terms of Use Terms of Sale Privacy Policy Shipping Policy | FAQ Technical Info Site Map |
- Internet prices apply only to Internet purchases.
- Minimum order amount is $20.00.
- All merchandise listed is in stock.
- Orders are shipped the next business day.
- We only sell within the 48 adjacent United States.
- Shipping tracking numbers are e-mailed automatically.
- Office hours are: Mon - Fri, 8am - 5pm EST excl. holidays.
TIMES