B/W Floatless Induction Type 115 Volt Liquid Level Control can be used as a pump-down or a pump-up water level control depending on contact arrangement.
Specifications
Pump-down: Pump starts when water level in the cistern, tank or well reaches upper electrode and stops when water level drops below the lower electrode.
Contact Arrangement for Pump-down: 2 Normally Closed (N.O)0 Normally Open (N.O.)
Note: Control factory set for pump-down operation
Pump-Up: Pump Stops when water level reaches the upper electrode and starts when water drops below the lower electrode.
Contact Arrangement for Pump-up: 1 Normally Open (N.O.)1 Normally closed (N.C.)
Enclosure: Nema 1 general purpose
Contact rating: 25 amps at 120. 240 or 480 Volts; 1 HP Single Phase at 120 or 240 Volts
Line Voltage: 110-120 Volts 50/60 Hz
Secondary Voltage: 360 Volts
Ground: A ground is required from the indicated relay terminal to the liquid in order to complete the secondary circuit of the relay. Connection should be made directly to the uninsulated metal tank, or to metal pipe connected to the tank below the normal liquid level control. in wells, concrete, or insulated metal tanks, an extra common electrode extending slightly below the longest operating electrode is used.
B/W Induction Relay Suspension Wire 200' Roll # AW23R2,
The B/W special induction relay suspension wire was designed to provide the required strength and flexibility for suspending electrodes in wells. It also assures a water-tight seal at the electrode junction. $39.00
Notice:Order suspension wire and electrodes separately (3 each electrodes for submersible well pump cut-off protection) .