Replaced by Grundfos 18 GPM 1 HP 230 V # MQ3-45-230 Booster Pumps
We no longer sell Davey Pumps. Davey Pumps has closed their USA factory warehouse and we have had numerous warranty issues with their products that we could not resolve to our customer's satisfaction.
Davey Pump Pressure Booster 20 GPM 40 PSI Boost 1 HP 230 V # BF20-40 with flow control, are ideal for shower boosting applications. They are not recommended for whole home applications. It requires a minimum of 20 psi inlet pressure for the flow control to operate
Applications:
- Shower boosting and irrigation applications only, they are not recommended for whole home applications.
Operation:
- When the flow is more than 1.2 GPM the pump will turn on and give up to an extra 38 PSI boost depending on the demand
- The pump will continue to run until the demand drops below 0.7 GPM
- If the main supply fails, the pump will stop.
- It will restart by itself when the city water pressure returns provided the flow is over 1.2 GPM
Specifications: Multiple stages ( 4 Impellers), self-priming centrifugal
Pump construction: 304 Stainless steel and corrosion-resistant materials.
Inlet & outlet: 1" FNPT X 1" MNPT(male pipe thread)
Cut-in flow: 1.2 GPM
Cut-out flow: 0.7 GPM
Maximum operating pressure: Cannot exceed 100 PSI
Tank size: None required Suction lift: Not capable of suction liftMaximum inlet pressure: 24 PSI (Must install a pressure reducing valve on the suction side of the pump if the inlet pressure is more than 24 PSI)
Electrical: 230 volts, 1 phase, 5.0 Amps., 60 Hz, 1 HP, TEFC motor. Includes 6' electrical cord less plug
Maximum allowable city pressure: 24 PSI
Maximum water temperature: 150 degrees Fahrenheit
Carton Dimensions: 14.54" high, 17.4" long, 7.85" wide.
Weight: 27.3 lbs.
Capacity Rating Chart
| Model |
HP |
Volts |
Amps |
Discharge Pressure Boost (PSI) |
Suction Lift In Feet |
| 0' |
5' |
10' |
15' |
20' |
Gallons Per Minute (GPM) |
| BF20-40
|
1 |
230 |
5.0 |
40 |
19.5 |
  |
  |
  |
  |
| 50 |
16.0 |
  |
  |
  |
  |
| 60 |
12.0 |
  |
  |
  |
  |
| Max. Pressure Boost |
76 PSI |
  |
  |
  |
  |
Do not exceed a total system pressure of 100 PSI.
The total system pressure will be the incomming city pressure plus the maximum output pressure from the data above.
Use a pressure regulating valve in the suction and /or discharge lines as required.
NOT AVAILABLE
|