Flojet Demand Pump 1 GPM 12VDC 25-35 PSI, LF122202D

replacement for the discontinued LF122202D
Flojet miniature, self priming LF12 series (LF-12V-V/S-2C SW35-PLT) automatic water system demand pump. Meets USCG electrical requirements, CSA Listed and IAPCO listed. Polypropylene housing, Santoprene diaphragm and EDPM check valve construction
Suitability for the application should be determined by actual use and is the full responsibility of the buyer. No warranty, expressed or implied, can be extended by the equipment manufacturer where failure is caused by chemical attack on pump materials. Temperature, aeration, concentration, and other factors may change the effect of the specific fluid on the pump materials. Only pumps with Santoprene / EPDM elastomers are recommended for potable water. Units are NOT designed for permanent residential domestic water applications.
If the fluid is improperly matched to the pumps Elastomers,
the pump may fail to prime, leak, have low pressures
or the pressure switch may not shut off.
Specifications
Applications: Agricultural products and backpak sprayer pump, air conditioning condensate return pump, beverage dispensing, floor care machines, hot dog carts, RV and marine automatic water systems, liquid transfer, spraying, cooling systems, circulation, filtration. Operation: These self priming double diaphragm pumps have a built-in pressure switch that will automatically start and stop the pump instantaneously when a discharge valve is opened and closed. Duty Cycle: Intermittent. Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump. Special Features: Self priming up to 4 ft. Can run dry for short periods of time. Chemical resistant materials. Built-in back flow preventer. Internal bypass standard. Includes: Pump, motor, pressure switch, motor mounting grommet kit. Motor: Permanent magnet, thermally protected 12 volt DC, 4 amps @ 10 PSI Pump: Two chamber positive displacement opposed diaphragm design Flow: 1.0 GPM Pressure setting: 25 PSI on, 35 PSI off Required fuse: 4 A fuse must be installed to meet CSA requirement Wetted Parts: Polypropylene housing, Santoprene diaphragm, EDPM check valves Minimum Tip Size: 072" Diameter Priming: Self priming up to 4 ft. Connections: 3/8" hose barb. Dimensions: 2.28" high, 3.5" wide, 6.37" length Weight: 1.3 lbs
Model | Max. GPM | Max. PSI | Amps | Diaphragm | Check Valves | Switch Setting | Connection |
---|---|---|---|---|---|---|---|
LF122202D | 1 | 35 | 4 | Santoprene | EDPM | 25-35 PSI | 3/8" Barb |
Resources
Questions & Answers
- What is the Flojet Pumps duty cycle?
- The Flojet manual states Intermittent duty. Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump.
- Can Flojet Pumps run continuously?
- Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump.
- What does short periods of time mean?
- Up 60 minutes with discharge pressure of up to 20 PSI. Up to 20 minutes when the discharge pressure is over 20 PSI. The off-time should be the same or more than the run time.
- What is meant by demand operation?
- Demand Operation is considered an “intermittent duty” application.
- What is an intermittent duty cycle?
- The maximum intermittent duty cycle is that which will cause the motor to reach its maximum thermal limits. Once the maximum thermal limit is reached, the motor must be allowed to settle to a lower temperature ideally being ambient before resuming operation. Running the pump at or near the maximum thermal limit for extended period of time will shorten the life of the pump and may result in immediate pump failure.
- What diaphragm and valve materials are recommended by Flojet for potable water?
- Only pumps with Santoprene / EPDM elastomers are recommended for potable water.
- Are Flojet pumps recommended for permanent residential domestic water applications?
- Units are NOT designed for permanent residential domestic water applications.