Your First Choice for Pumps and Pump Systems
Call Icon Call (305)-754-0677 M-F 8am - 4pm EST | Contact | FAQ

Flojet Quad II Demand Pump 4.9 GPM 12 VDC 45 PSI # 4300-143A

Item#: FJC-PMP-04300-143A
Product Available Availability:Usually ships the next business day
Flojet Quad II Demand Pump 4.9 GPM 12 VDC 45 PSI # 4300-143A (CC) <br>
Reg. $279.52
Sale: $193.60

Flojet 4.9 GPM Quad II Automatic 12 Volt DC, 45 PSI, Self Priming Demand Water Pumps are designed for a wide range of applications and are constructed from a selection of materials suitable for handling a broad range of products.

Suitability for the application should be determined by actual use and is the full responsibility of the buyer. No warranty, expressed or implied, can be extended by the equipment manufacturer where failure is caused by chemical attack on pump materials. Temperature, aeration, concentration, and other factors may change the effect of the specific fluid on the pump materials. Only pumps with Santoprene / EPDM elastomers are recommended for potable water. Units are NOT designed for permanent residential domestic water applications.

Do not assume chemical compatibility.
If the fluid is improperly matched to the pumps Elastomers,
the pump may fail to prime, leak, have low pressures
or the pressure switch may not shut off.

Specifications

Applications: Automatic water systems, liquid transfer, spraying, cooling, circulation, filtration and dispensing. Operation: These self priming double diaphragm pumps have a built-in pressure switch that will automatically start and stop the pump instantaneously when a discharge valve is opened and closed. Duty Cycle:Intermittent. Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump. Special Features: Self priming up to 8 ft. Can run dry for short periods of time. Chemical resistant materials. Heavy duty ball bearing drive system. Built-in back flow preventer. Internal bypass standard Includes: Pump, motor, # 2090104 (45 PSI) pressure switch, 20132-000 motor mounting grommet kit, # Two 20381-006 straight 3/4" hose barb adapters. Motor:Permanent magnet, thermally protected 12 volts, DC, 13.0 amps, ball bearings Pump:Two chamber positive displacement opposed diaphragm design Pressure setting: 30 PSI Cut-in, 45 PSI Cut-out Maximum Operating Pressure: 40 PSI Maximum suction pressure: 30 PSI Wetted Parts:Modified polypropylene housing, Buna N check valves, Santoprene diaphragm. Priming:Self priming up to 8 ft. Minimum Spray Tip Required: 9/64" (Spraying applications only) Connections: Plug-in ports to accept removable adapters. 3/4" hose barb adapters included (0-ring material EPDM). Other adapters available for easy installation. Dimensions: 4" high, 10" long, 4" wide. Weight: 5 lbs

Flojet 12 Volt DC Demand Pumps Specification Comparison Table
Model Max. GPM Max. PSI Amps Diaphragm Check Valves Switch Setting Connection
4300-143A 4.9 45 13.0 Santoprene Buna 30-45 PSI 3/4" Barb

Pump Capacity Table
Model Head In PSI
0 10 20 30 40 Shut-off
Gallons Per Minute (GPM)
4300-143A 4.9 4.2 3.8 3.4 3.0 45 PSI

You May Also Like

Flojet Inline Strainer 3/4" Barb X Quad 40 Mesh, 7 GPM @ 70 PSI  #  01740-010(C) <br>Flojet Inline Strainer 3/4" Barb X Quad 40 Mesh, 7 GPM @ 70 PSI # 01740-010(C)
$27.48
$20.00
Flojet Inline Strainer 1/2" Barb X Quad 40 Mesh, 7 GPM @ 70 PSI  #  01740-012 (C)<br>Flojet Inline Strainer 1/2" Barb X Quad 40 Mesh, 7 GPM @ 70 PSI # 01740-012 (C)
$27.48
$20.00

Questions & Answers

The Flojet manual states Intermittent duty. Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump.
Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump.
Up 60 minutes with discharge pressure of up to 20 PSI. Up to 20 minutes when the discharge pressure is over 20 PSI. The off-time should be the same or more than the run time.
Demand Operation is considered an “intermittent duty” application.
The maximum intermittent duty cycle is that which will cause the motor to reach its maximum thermal limits. Once the maximum thermal limit is reached, the motor must be allowed to settle to a lower temperature ideally being ambient before resuming operation. Running the pump at or near the maximum thermal limit for extended period of time will shorten the life of the pump and may result in immediate pump failure.
Only pumps with Santoprene / EPDM elastomers are recommended for potable water.
Units are NOT designed for permanent residential domestic water applications.