Flojet Demand Pump 1 GPM 12VDC 25-35 PSI, LF122202D

Flojet  Demand Pump 1 GPM 12VDC 25-35 PSI, LF122202D (B)
LFP122202D is Flojet's
replacement for the discontinued LF122202D

Flojet miniature, self priming LF12 series (LF-12V-V/S-2C SW35-PLT) automatic water system demand pump. Meets USCG electrical requirements, CSA Listed and IAPCO listed. Polypropylene housing, Santoprene diaphragm and EDPM check valve construction

Suitability for the application should be determined by actual use and is the full responsibility of the buyer. No warranty, expressed or implied, can be extended by the equipment manufacturer where failure is caused by chemical attack on pump materials. Temperature, aeration, concentration, and other factors may change the effect of the specific fluid on the pump materials. Only pumps with Santoprene / EPDM elastomers are recommended for potable water. Units are NOT designed for permanent residential domestic water applications.

Do not assume chemical compatibility.
If the fluid is improperly matched to the pumps Elastomers,
the pump may fail to prime, leak, have low pressures
or the pressure switch may not shut off.

Specifications

Applications: Agricultural products and backpak sprayer pump, air conditioning condensate return pump, beverage dispensing, floor care machines, hot dog carts, RV and marine automatic water systems, liquid transfer, spraying, cooling systems, circulation, filtration. Operation: These self priming double diaphragm pumps have a built-in pressure switch that will automatically start and stop the pump instantaneously when a discharge valve is opened and closed. Duty Cycle: Intermittent. Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump. Special Features: Self priming up to 4 ft. Can run dry for short periods of time. Chemical resistant materials. Built-in back flow preventer. Internal bypass standard. Includes: Pump, motor, pressure switch, motor mounting grommet kit. Motor: Permanent magnet, thermally protected 12 volt DC, 4 amps @ 10 PSI Pump: Two chamber positive displacement opposed diaphragm design Flow: 1.0 GPM Pressure setting: 25 PSI on, 35 PSI off Required fuse: 4 A fuse must be installed to meet CSA requirement Wetted Parts: Polypropylene housing, Santoprene diaphragm, EDPM check valves Minimum Tip Size: 072" Diameter Priming: Self priming up to 4 ft. Connections: 3/8" hose barb. Dimensions: 2.28" high, 3.5" wide, 6.37" length Weight: 1.3 lbs



Flojet 12 Volt DC Demand Pumps Specification Comparison Table
Model Max. GPM Max. PSI Amps Diaphragm Check Valves Switch Setting Connection
LF122202D 1 35 4 Santoprene EDPM 25-35 PSI 3/8" Barb

FJC-PMP-LF122202D-Diaphragm-Bulletin.pdf
FJC-PMP-LF122202D-Diaphragm-Manual.pdf

Flojet Strainer 3/8" FNPT, 40 Mesh, 2 GPM @ 70 PSI  # 01740-375 (C)<br>

Flojet inline strainer # 01740-375, 3/8" FNPT connection, 2 GPM at 70 PSI maximum capacity, 40 mesh stainless steel screen.

List: $27.48
Value Priced $20.00
Availability: ships the next business day
FJC-ACC-01740-375S

Questions & Answers

What is the Flojet Pumps duty cycle?
The Flojet manual states Intermittent duty. Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump.
Can Flojet Pumps run continuously?
Can be run continuously for short periods of time. The higher the duty cycle the shorter the expected life of the pump.
What does short periods of time mean?
Up 60 minutes with discharge pressure of up to 20 PSI. Up to 20 minutes when the discharge pressure is over 20 PSI. The off-time should be the same or more than the run time.
What is meant by demand operation?
Demand Operation is considered an “intermittent duty” application.
What is an intermittent duty cycle?
The maximum intermittent duty cycle is that which will cause the motor to reach its maximum thermal limits. Once the maximum thermal limit is reached, the motor must be allowed to settle to a lower temperature ideally being ambient before resuming operation. Running the pump at or near the maximum thermal limit for extended period of time will shorten the life of the pump and may result in immediate pump failure.
What diaphragm and valve materials are recommended by Flojet for potable water?
Only pumps with Santoprene / EPDM elastomers are recommended for potable water.
Are Flojet pumps recommended for permanent residential domestic water applications?
Units are NOT designed for permanent residential domestic water applications.

Ask a question about Flojet Demand Pump 1 GPM 12VDC 25-35 PSI, LF122202D (B). Click here
Customer Reviews



About Us Contact Us Customer Reviews Facebook Twitter Disclaimers Privacy Policy Returns Shipping Policy Terms of Sale Terms of Use Warranty FAQ Site Map Technical Info Terminology Troubleshooting
  • Internet prices apply only to Internet purchases.
  • Minimum order amount is $20.00.
  • All merchandise listed is in stock.
  • Orders are shipped the next business day.
  • We only sell within the 48 adjacent United States.
  • Shipping tracking numbers are e-mailed automatically.
  • Office hours are: Mon - Fri, 8am - 4:30pm EST excl. holidays.
Copyright © 2012 All Rights Reserved.