 | Brady air volume control model AV 42T, AV80T, AV100, AV120. Zinc die cast body, Buna N diaphragm and seal cap elastomers, brass spring and orifice; 100 PSI maximum pressure. |
|
 | Aquastats or hot water controls for limiting or regulating temperature of liquids. Used on hot water heating installations. May be used as a high limit, low limit circulator control or combination low limit- circulator applications. Avialable for strap-on, inmersion or clip-on mounting. |
|
 | Brady Plastic Spring Loaded Foot Valves / Check Valves; Flo-Control compression, solvent weld and true union swing check valves; Strataflo noiseless spring loaded brass check valves and brass foot valves; high pressure small brass check valves |
|
 | Duplex Waterproof Control Panels For Wastewater Pumps. Duplex waterproof control panels with hand-off-auto switches, running lights, (H-O-A) elapse time meters for each pump plus a visual flashing high water alarm, and a pulsating high water alarm horn with silence button in a Nema 4X water-proof fiberglass enclosure for a variety of sump, effluent, sewage and water transfer applications. |
|
 | Electrical controls include aquastats / temperature controls, wastewater duplex control panels, induction relays, liquid level float switches, mounting brackets & alarms, ground fault interrupter, pressure switches, timers, submersible well pump control box, vacuum switch / pump protector |
|
 | The tape method was the only way to make a good splice until shrink tube splice kits became available. Many installers still use tape because it has worked for them for years. You crimp the conductors together, wrap each conductor with a layer of rubber tape followed with a layer of plastic electrical tape. This makes a watertight connection and insulates the conductors from each other and the well casing. Properly done, this technique makes an excellent splice, but is very time consuming. |
|
 | Flexible 3/8" to 1" smooth vinyl tubing and 1-1/4" to 1-1/2" corrugated black vinyl hoses which are practically invisible beneath the water service. The black color inhibits algae growth inside the tubing. |
|
 | Franklin Electric single-phase control boxes for 1/2 to 5 horsepower submersible motors; Type 3R enclosure suitable for outdoor mounting, not gasketed, two holes for wall mounting at back of box; knockouts in the bottom and sides; UL recognized and CSA certified
|
|
 | Franklin Electric Motor 4", 3 wire, single phase, 60 Hz, 1/2 HP to 5 HP,water cooled, submersible water well motors with 48" Leads and control boxes. Single phase three-wire submersible motors require the use of control boxes. |
|
 | These 4 wire, black, heavy wall heat shrink splicing kits can be shrunk over a large diameter connector and still effectively seals watertight to a small diameter cable. Four butt connectors are included.Slip shrink tube on each wire, crimp connector on each wire, center tubing over connector and heat from center outward, splice is complete when sealant flows fron end of tube. Do not overheat |
|
 | Polypropylene 3/8" to 1-1/4" male pipe thread to 3/4 male hose thread adapters and male pipe thread by hose barb insert adapters. |
|
 | Blue PVC, light weight, mildew resistant, water discharge hoses for moderate discharge service. Discharge hoses roll up flat for easy storage. Suction and discharge hoses come equipped with one male and female IPT connection. Plastic discharge street elbow, quick couplers and suction strainers |
|
 | The Hudson Valve's unique design maintains fluid level in various applications replacing other kinds of valves. The valve operates an exceptional patented float system. |
|
 | Jet Pumps accessories include air volume controls; check valves, foot valves, float valves, pressure gauges, pressure relief valve, PVC ball valves, PVC fittings, pressure tanks, priming tee and well seals |
|
 | Leader accessories include plastic check valve, plastic foot valve, multihose adapter, hose adapter and 1-14" X 24' discharge hose. |
|
 | Alarm systems are to be used whenever liquid levels need to be monitored. In the event of pump malfunction, power loss or circuit failure, a system of lights and audible alarms can alert the resident or service personnel of the problem. |
|
 | Floatless induction type level switches, diaphragm "piggy back" switches, narrow & wide angle control rated & pump rated float switches |
|
 | Franklin Monodrive variable speed constant pressure controllers are designed to provide constant pressure for single-phase, three-wire submersible water well pump systems. You can have constant pressure just by replacing the three-wire control box in a conventional system. |
|
 | PVC Ball Valves 3/4", 1 ",
1-1/4", 1-1/2", 2", 3" and 4" PVC ball valves are constructed of quality materials using virgin schedule 80 PVC EPDM seats and seals. Rated 150 PSI at 72 degrees Fahrenheit water temperature. Full port flow opening, quarter turn operation. Fit schedule 40 and 80 pipes. Solvent ends comply with ASTM D2466. Materials meet NSF standards. Usually ships the next business day. |
|
 | PVC schedule 40 NSF fitting from 1/2" to 6". PVC fittings never rust, scale, or pit. PVC can handle fluids up to 140°F. Lower material costs, lighter weight and ease of installation, can reduce costs by as much as 60% over metal systems. Smooth interior walls result in lower pressure loss and higher volume than conventional metal fittings. PVC Valve products are available for total system compatibility and uniformity; NOT FOR USE WITH COMPRESSED AIR OR GAS |
|
 | Bronze pitless adapters to insure long life and durability in the most aggressive well conditions. External installation nipple makes installation easy.Rubber inner & outer casing gaskets for certified & approved water tight seal from ground water contamination. |
|
 | Polypropylene pipe and fittings can be used for industrial applications involving corrosive media. Polypropylene may be used at temperatures up to 150º F in continuous pressure service. Polypropylene is the lightest of all thermoplastics. It has good resistance to strong acids except highly active oxidizers, such as nitric acid. Polypropylene also has excellent resistance to weak and strong alkalis and to most organic solvents and is also a non-conductor of electricity. Polypropylene fittings are designed for pressure up to 150 psi at 70-deg F. We carry a complete line of injection molded polypropylene fittings, which includes male adapters, female adapters, couplings, elbows, tees, bushings and hose adapters. |
|
 | Test Gauges with hose swivel connection & glycerine liquid filled vacuum & pressure stainless steel gauges that dampen the effects of pulsation and vibration which will extend their life.Use only with water |
|
 | Pressure reducing valves (also called PRV's), are compact, inexpensive devices that perform two functions: (1) they automatically reduce the high incoming
water pressure from the city mains to provide a lower,
more functional pressure for distribution in the home;
(2) they "regulate" by maintaining a set pressure in the
home usually 50 psi -- thereby insuring that the home
piping and appliances operate under a safe, more
moderate, but satisfactory pressure.
|
|
 | Pressure relief valve 1/2" heavy duty, no lead, bronze pressure relief valve for shallow, deep well and submersible pumps. Recommended only for cold water system installation. Spring loaded and pre-set at 100 PSI (Not adjustable). Not for use with hot water heaters. |
|
 | The pressure switch starts and stops the pump motor automatically at a predetermined pressure. A tube connects the switch to some point in the system on the discharge side of the pump. The pressure in the system then acts directly on a diaphragm in the switch, which in turn actuates the contacts in the switch. |
|
 | In a closed, automatic water system a pressure tank is used to store water and maintain system pressure between specified limits (such as 30 to 50 PSI). As the water level in the tank rises, tank air is compressed until the cut-out pressure is reached. At this "cut-out" point a pressure switch opens the electrical circuit to the motor and the pump stops.
The compressed air in the tank acts like a spring pushing down on the water to create system pressure. When a valve is opened in the water system, the air pressure in the the tank forces water to flow out of the tank and into the system. As the water is drawn from the tank, the air occupies a larger space and the pressure drops until the lower limit is reached (i.e., 30 PSI), At this cut-in point the pressure switch closes the electrical circuit to the motor and the pump starts. A cycle is thereby completed. |
|
|
 | No Longer Available. The Polyslab pump and motor cover is light and easy to use. Polyslab polymer design does not chip, crack, grow mould or corrode like concrete. The Polyslab has multiple ventilation points for flow through ventilation. Easy to follow cut and snap entry points allow for common pipe dimensions. The Polyslab cover includes a matching base which is designed to raise the pump off the ground and can easily removed if required. We offer Polyslab pump and motor covers in tan only. |
|
 | It shields and protects outdoor motors from the sun, rain and dust. |
|
 | PumpTec Automatic Protection Control For Franklin Submersible Motors, Single-phase, solid state, load monitoring devices designed specifically for Franklin submersible motors to protect from running dry. They protects the life of 4" submersible pump and reduces the odds of ever having to see the motor again |
|
 |
Simplex waterproof control panel # BF120S-S740 with hand-off-auto switch, running light, (H-O-A) elapse time meter for pump plus a visual flashing high water alarm, and a pulsating high water alarm horn with silence button in a Nema 4X water-proof fiberglass enclosure for a variety of sump, effluent, sewage and water transfer applications. |
|
 | The Conery BERS-0200 Base Elbow Rail System is designed for simple installation and removal of most vertical
discharge pumps. Its innovative design allows for pump service without the need to disconnect plumbing
or physically enter the basin. Pump not included |
|
 | Suction and discharge oil filled pressure gauges; plastic and bronze check valves and foot valves; sprinkler timers; PVC ball valves |
|
 | Intermatic 24 Hour Electric Sprinkler Timer. Rainproof enclosure with provision for rain sensor. Built-in pump start relay. On-off switch allows for shutdown during rainy days. 14 day skipper wheel permits watering to be omitted on selective days. |
|
 | Submersible pump cable 12/4 (3-wire plus ground) UL listed 3 wire copper cable (with ground) for use within the well casing supplying power to the submersible pump. |
|
 | Accessories for submersible sump, effluent and sewage pumps including check valves, ball valves, high level alarms, float switches and mounting brackets |
|
|
 | High Liquid Temperature Relief Valve # TOT-VLV-1/4ECONO-HAT/RA-105M/F. The model ECONO/HAT/RA reverse acting mechanical (self-operating) temperature valve requires no outside power. It modulates throughout the temperature range to conserve liquid media, yet will eliminate large quantities of over-temperature liquid if required. It is unaffected by pressure variations. |
|
 | Torque arrestors are clamped on the submersible well pump drop pipe and are field adjusted to hold the pump centered in the well casing. Fits 4"-8" well casings and 1 or 1-1/4 drop pipe. |
|
 | This vacuum switch is intended to automatically shut off the pump electric motor when liquid is depleted or when the vacuum suction drops to a certain level. |
|
 | PVC Ball Valves, Bronze Check Valves , Plastic Check Valves Float Valves, Bronze Foot valves, Plastic Foot valves, Indexing Valves, Level Control Valves, Pressure Relief Valves, Pressure Regulating Valves, Temperature Relief Valves |
|
 | Cast Aluminum standard ventilated
well cap with conduit opening. Standard 4". 5" and 6" cast aluminum well caps for use on steel or plastic casiing. Stainless steel set screws |
|
 | Submersible Well Pump Accessories. Torque Arrestors, Submersible Pump Cable, Well Seals, Bronze Pitless Adapters, Franklin Electric Pump Control Boxes, Sprinkler Timers, Strataflo Bronze Check Valves, Flo-Control PVC Check Valves, Pressure Switches, Liquid Filled Pressure Gauges, Wellmate Fiberglass Pre-charged Bladder Water Pressure Tanks and Pressure Relief Valves. |
|
 | Cast iron well seal with rubber packing gland for submersible and jet pumps. Prevents contamination from surface drainage. Easy to install, just fit in casing and tighten bolts. Corrosion resistant zinc plated steel bolts. Painted finish. Split top |
|